| Eddy Current
| Principle | Electromagnetic induction for non-ferromagnetic materials |
| Defect detection | Cracks, corrosion, erosion, pitting, thickness loss, and mechanical damage at surface and/or near-surface level |
| Typical applications | Covers the surface and near-surface level of the parts to be inspected, depending on the material characteristics |
| Typical equipment | Heat exchangers, acid coolers, condensers, boilers, tanks, piping, alloy structures, gears, etc. |
| Typical materials | Non-ferromagnetic alloys such as titanium, stainless steel 304, 310, 316, zirconium, austenitic steels (Saramet, Zecor, SX, etc.), aluminum, and copper |
| Restrictions | Only electromagnetically conductive metallic materials. Sensitive to changes in metal permeability and surface cleanliness conditions |
Introduction
Among non-destructive testing methods, the Eddy Current technique — or induced current testing — is one of the best methods for evaluating the condition of heat exchanger tubes.
However, tubes in many types of equipment, such as condensers, coolers, water heaters, and preheaters, can also be inspected using this technique in order to prevent unexpected shutdowns.
Routine and planned NDT inspections such as Eddy Current testing result in very significant improvements in equipment reliability and plant availability.
Avoiding unplanned shutdowns leads to significant cost savings and practically eliminates production losses caused by asset unavailability.
Aplicaciones
The Eddy Current technique is one of the most widely used inspection techniques for assessing the condition of tubes in different types of heat exchangers.
It is applicable to non-ferromagnetic materials or alloys such as titanium, stainless steels like 304, 310, and 316, zirconium, and austenitic steels with high silica content such as Saramet, Zecor, and SX.
Defects such as pitting, erosion, corrosion, fretting, and cracks can be detected.
How It Works
Eddy Current inspection uses electromagnetic induction to identify defects in tubes.
A probe is inserted into the tube and pushed along its entire length.
Eddy currents, or induced currents, are generated by the electromagnetic coils inside the probe and simultaneously monitored by measuring the electrical impedance of the probe.
Changes in impedance detected by the probe will reveal tube defects.
All scanned data is analyzed, recorded, and stored by the instrument.
Advantages
- It is suitable for volumetric defects such as corrosion, wear, large porosities, as well as cracks
- In the case of some defects, such as pitting and corrosion, the Eddy Current technique can distinguish whether the defect exists on the inside or outside of the tube
- A highly relevant advantage of Eddy Current inspection is that defect detection is instantaneous and can be immediately reported to those responsible
Disadvantages and Limitations
- The tubes must be clean, mainly because the inspection probe has a slightly smaller diameter than the inner diameter of the tube.
Any contamination inside the tubes affects the quality of the information collected during the inspection, in addition to the fact that any dirt present inside the tubes may damage the probe - Defects near the heat exchanger tube sheet are difficult to detect. In such cases, it is recommended to combine EC with Airborne Ultrasound.