| Magnetic Particle Testing
| Principle | Magnetic field induction. |
| Defect Detection | Surface or near-surface defects or discontinuities such as cracks, pores, voids, etc. |
| Typical Applications | Weld beads, structures, hooks, and carbon steel components. |
| Typical Equipment | Welded joints, crane hooks, trunnions, metal structures, various components. |
| Typical Materials | Ferromagnetic materials |
| Restrictions | Not suitable for non-ferromagnetic alloy materials. Surfaces must be completely clean of dirt, grease, or oils, and free of any type of coating. |
Introduction
The magnetic particle inspection is a type of non-destructive testing that allows the detection of surface and subsurface discontinuities in ferromagnetic materials.
This technique enables the detection of cracks and other discontinuities both on the surface and near-surface. This capability allows the inspection of materials with coatings, such as thin layers of paint.
Sensitivity is highest for surface discontinuities and decreases as their depth increases.
Applications
It is used when a faster inspection is required compared to liquid penetrant testing. Some examples of inspections that can be performed with magnetic particles include:
- Weld inspection
- Inspection of weld edge preparations
- Inspection of metal components: forged parts, castings, machined parts, etc.
This technique is applied both to parts during manufacturing (in workshops) and to field installations. It is used for the detection of surface discontinuities up to 1/4″ deep and is particularly applied to ferromagnetic materials.
How It Works
It is a method that mainly uses electric current to create a magnetic flux in a part. Magnetic particles are applied in spray form, and then the indications produced by the accumulation of these particles in certain areas are evaluated.
The process varies depending on the materials used, the defects being sought, and the physical conditions of the part being inspected.
Advantages
- The inspection is faster than liquid penetrant testing.
- The inspection equipment is relatively simple.
- The surface of the part requires less cleaning than in the case of liquid penetrant testing.
- It detects both surface and subsurface discontinuities.
- The indications are produced directly on the surface of the part, showing the length, location, size, and shape of the discontinuities.
Disadvantages and Limitations
- It will not detect discontinuities deeper than 1/4″.
- It is only applicable to ferromagnetic materials.
- It requires a power source.
- It cannot be applied if the paint coating is too thick.
- Interpreting indications requires experience.