| Remote Field Testing
| Principle | Electromagnetic induction for ferromagnetic materials |
| Defect Detection | Cracks, corrosion, wall loss, etc. |
| Typical Applications | Heat exchanger and boiler tubes. |
| Typical Equipment | Boilers, heat exchangers, and heaters. |
| Typical Materials | Ferromagnetic materials such as carbon steel (SA 178, 179, 192, etc.). |
| Restrictions | Only electromagnetically conductive metallic materials. Sensitive to changes in metal permeability and surface cleanliness conditions. |
Introduction
In the field of non-destructive testing, the RFT technique is associated with the Eddy Current, or Induced Current, technique.
Both are screening techniques used to evaluate the condition of heat exchanger tubes. RFT is applied for the inspection of tubes manufactured from ferromagnetic materials or slightly austenitic alloys.
Performing routine NDT inspections such as RFT results in very significant improvements in equipment reliability and plant availability.
Applications
The RFT technique is applied in the inspection of ferromagnetic material tubes, where the conventional Eddy Current technique cannot be used.
The use of carbon steel tubes is common in equipment such as boilers, heat exchangers, and air heaters, which is why RFT is the most widely used technique for these types of equipment.
It is a very suitable method for the detection and quantification of material loss in tube walls caused by corrosion.
Local defects can be detected and quantified as long as they have a certain volume. With RFT, both internal and external defects can be detected, although it is not possible to distinguish between them.
How It Works
RFT inspection uses electromagnetic induction to identify defects in tubes.
A probe is inserted into the tube and pushed along its entire length. The probe consists of a transmitter or exciter coil and a receiver coil; there is a distance of approximately two tube diameters between the coils.
The exciter coil is driven by a relatively low alternating current to produce a magnetic field. This field travels from the exciter coil through the tube wall and along the outside of the tube.
Therefore, there are two paths between the transmitter and the receiver: the direct path through the wall, where the magnetic field is rapidly attenuated by the induced circumferential eddy currents, and the indirect path, where the magnetic field travels along the outside of the tube wall.
Any anomaly in the indirect path causes changes in the received signal, which are used to detect defects.
Advantages
- It is highly suitable for ferromagnetic materials.
- It has the same sensitivity for internal and external defects.
- It is a robust method and not highly sensitive to probe movement relative to the tube.
Disadvantages and Restrictions
- The tubes must be clean, mainly because the inspection probe has a diameter slightly smaller than the inner diameter of the tube. The presence of any material inside the tube affects the quality of the information collected during the inspection. In addition, material present inside the tube may cause damage to the probe.
- It is difficult to detect defects near the tube sheet of the heat exchanger.