| Tangential Eddy Current Array
| Principle | Electromagnetic induction for ferromagnetic materials |
| Defect Detection | Surface cracks in ferromagnetic materials |
| Typical Applications | Carbon steel welds and other ferromagnetic components. |
| Typical Equipment | Heat exchanger and boiler tubes, mining truck chassis, storage tank welds, piping, manufactured components |
| Typical Materials | Carbon steels such as SA 178, 179, 192, etc. |
| Restrictions | Only electromagnetically conductive metallic materials; access to the defect area is required |
Introduction
TECA technology, or Tangential Eddy Current Array, is, within the field of non-destructive testing, the ideal technology for detecting and sizing surface cracks in ferromagnetic materials.
Carbon steel inspection continues to be a challenge in the field of non-destructive testing, especially because cracks in welds are difficult to detect.
However, the TECA technique offers a very good alternative to traditional testing methods such as Magnetic Particle Testing and Liquid Penetrant Testing.
The probability of detecting defects with TECA is significantly higher than with Magnetic Particle Testing.
Applications
TECA testing is relatively simple since the surface does not require the same preparation needed by traditional methods.
This characteristic, combined with the high inspection resolution capable of detecting defects with a depth of up to 10 mm, makes TECA the ideal technique for inspecting carbon steel welds in a wide variety of applications.
Some examples include: inspection of the weld between tubes and the tube sheet in heat exchangers; inspection of the chassis of CAEX mining trucks; inspection of tank and piping welds; and manufactured components.
How It Works
“Tangential” refers to the orientation of the coils and Eddy currents induced in the material.
The Eddy currents flow parallel to the surface of the tested component. When a crack opens on the surface, the Eddy currents are forced to flow beneath it, reducing the density of the Eddy currents at the surface.
TECA uses this variation in current density to determine the depth of the crack being examined.
Characteristics and Advantages
- No extensive surface preparation is required.
- TECA provides continuous measurement across the entire surface of the component.
- It is a non-contact method that allows inspection of coated surfaces, permitting up to 3 mm of probe lift-off from the surface.
- Crack sizing in both length and depth, up to 10 mm deep.
- Detection sensitivity is similar to, if not better than, conventional methods such as magnetic particle testing and liquid penetrant testing.
- The inspection has relatively high productivity.
- Possibility of obtaining a defect map of the inspected surface.